TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 585 of 1432

Change 1 2-1589 TM 9-2320-365-20-2 CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P116-32. (3) Connect negative (-) probe of multimeter to connector PX33P and note reading on multimeter. (4) Connect negative (-) probe of multimeter to all other sockets in connector PX33, one at a time, and note reading on multimeter. (5) If continuity is not present in step 3, or continuity is present in step 4, repair wire 143 (para 2-40) or replace WTEC III dashboard cable assembly (para 7-11). (6) Connect connector PX33 to WTEC III TPSS. (7) Install instrument panel assembly (para 7-15). (8) Clear diagnostic codes (para 8-5).