TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 58 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1112 2-1112 2-1112 2-1112 2-1112 TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 3. YES NO If continuity is not present, wire 706C is faulty. Repair or replace wire 706C (para 2-40). 110 vac outlets OK. Circuit breaker CB6 OK. Wire 708BB OK. POSSIBLE PROBLEMS Faulty wire 706C. Faulty INTERIOR LIGHTS switch S32. Faulty wire 706B. Faulty relay K41. Is continuity present on wire 706C from K41 relay base terminal 6 to bottom left pole of INTERIOR LIGHTS switch S32? e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT)