TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1111 2-1111 2-1111 2-1111 2-1111 CONTINUITY TEST (1) Loosen screw in cover. (2) Open cover on relay box assembly. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to output terminal of circuit breaker CB6. (5) Connect negative (-) probe of multimeter to K41 relay base terminal 9 and note reading on multimeter. (6) If continuity is not present, repair or replace wire 708BB (para 2-40). (7) Install cover on 110/208 VAC POWER DISTRIBUTION PANEL with six screws.