TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 56 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1110 2-1110 2-1110 2-1110 2-1110 YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 POSSIBLE PROBLEMS 2. If continuity is not present, wire 708BB is faulty. Faulty wire 708BB. Faulty wire 706C. Faulty INTERIOR LIGHTS switch S32. Faulty wire 706B. Faulty relay K41. 110 vac outlets OK. Circuit breaker CB6 OK. Is continuity present on wire 708BB from circuit breaker CB6 to K41 relay base terminal 9? Repair or replace wire 708BB (para 2-40). e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT) e102. ALL M1079 FLOURESCENT LIGHTS DO NOT OPERATE (CONT)