CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. CONTINUITY TEST Change 1 2-1483 TM 9-2320-365-20-2 (1) Connect connector P116 to WTEC II VIM. (2) Tighten screw in connector P116. (3) Remove instrument panel assembly for access (para 7-15). (4) Disconnect connector J115 from WTEC II TEPSS. (5) Set multimeter ohms. (6) Connect positive (+) probe of multimeter to connector P115 socket 2. (7) Connect negative (-) probe of multimeter to connector J115 socket 11 and note reading on multimeter. (8) If continuity is not present, replace WTEC II cab transmission harness (para 7-86). (9) If continuity is present, replace WTEC II TEPSS (para 8-2). (10) Install kick panel (para 16-3). (11) Connect batteries (para 7-48).