CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to WTEC II connector pin L2. (3) Connect negative (-) probe of multimeter to WTEC II connector pin K2 and note reading on multimeter. (4) If continuity is not present, replace WTEC II VIM (para 8-6). (5) Connect connector PX33 to WTEC II VIM. (6) Tighten screw in connector PX33. TM 9-2320-365-20-2 Change 1 2-1482.27