TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 443 of 1432

CAUTION Use care when testing electrical connectors not to bend connector pins or damage connector sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. CONTINUITY TEST TM 9-2320-365-20-2 Change 1 2-1482.13 (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector J115 from WTEC II TEPSS connector. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector J116 socket E2. (5) Connect negative (-) probe of multimeter to connector J115 socket 11 and note reading on multimeter. (6) Connect negative probe (-) of multimeter to all other sockets in connector J115 and note reading on multimeter. (7) Connect negative probe (-) of multimeter to ground and note reading on multimeter. (8) If continuity is not present in step (5), or continuity is present in step (6) or step (7), replace WTEC II cab transmission harness (para 7-86).