TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 43 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1097 2-1097 2-1097 2-1097 2-1097 CONTINUITY TEST (1) Loosen terminal 1 screw on fan terminal board. (2) Remove wire 3085X from fan terminal board. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to wire 3085X terminal lug. (5) Connect negative (-) probe of multimeter to other end of wire 3085X and note reading on multimeter. (6) If continuity is not present, repair or replace wire 3085X. (7) Position wire 3085X in fan terminal board. (8) Tighten terminal 1 screw on fan terminal board.