TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 42 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 8. Fluorescent lights OK. Circuit breaker CB8 OK. Fan switch S35 OK. Fan OK. Wire 415 OK. Wire 415A OK. Wires 1499H OK. POSSIBLE PROBLEMS Faulty wire 3085X. Faulty wire 3085F. Faulty wire 3085Z. Is continuity present on wire 3085X from one end to the other? If continuity is not present, wire 3085X is faulty. Repair or replace wire 3085X (para 2-40). e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) 2-1096 2-1096 2-1096 2-1096 2-1096