TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1095 2-1095 2-1095 2-1095 2-1095 CONTINUITY TEST CONTINUITY TEST (1) Loosen screw in terminal board TB4. (2) Remove wire 1499H from terminal board TB4. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to wire 1499H in power distribution panel. (5) Connect negative (-) probe of multimeter to wire 1499H in fan switch S35 outlet box and note reading on multimeter. (6) If continuity is not present, repair or replace wire 1499H (para 2-40). (7) Position wire 1499H in terminal board TB4. (8) Tighten screw in terminal board TB4. (1) Loosen screw on fan terminal board. (2) Remove wire 1499H from fan terminal board. (3) Set multimeter to ohms. (4) Connect positive (+) multimeter to wire 1499H. (5) Connect negative (-) probe of multimeter to wire 1499H and note reading on multimeter. (6) If continuity is not present, repair or replace wire 1499H (para 2-40). (7) Position wire 1499H in fan terminal board. (8) Tighten screw on fan terminal board.