TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 40 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 6. Fluorescent lights OK. Circuit breaker CB8 OK. Fan switch S35 OK. Fan OK. Wire 415 OK. Wire 415A OK. POSSIBLE PROBLEMS Faulty wire 1499H. Faulty wire 3085X. Faulty wire 3085F. Faulty wire 3085Z. Is continuity present on wire 1499H from one end to the other? If continuity is not present, wire 1499H is faulty. Repair or replace wire 1499H (para 2-40). YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 POSSIBLE PROBLEMS 7. Fluorescent lights OK. Circuit breaker CB8 OK. Fan switch S35 OK. Fan OK. Wire 415 OK. Wire 415A OK. Faulty wire 1499H. Faulty wire 3085X. Faulty wire 3085F. Faulty wire 3085Z. Is continuity present on wire 1499H from power distribution panel to fan switch S35 outlet box? If continuity is not present, wire 1499H is faulty. Repair or replace wire 1499H (para 2-40). e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) 2-1094 2-1094 2-1094 2-1094 2-1094