TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1093 2-1093 2-1093 2-1093 2-1093  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  output terminal of circuit breaker CB8.  (3) Connect negative (-) probe of multimeter to  wire 415 terminal lug in fan switch S35 outlet  box and note reading on multimeter.  (4) If continuity is not present, repair or replace  415 (para 2-40).  CONTINUITY TEST  (1) Loosen terminal 4 screw on fan terminal board.  (2) Remove wire 415A from fan terminal board.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter to  wire 415A terminal lug.  (5) Connect negative (-) probe of multimeter to  other end of wire 415A and note reading on  multimeter.  (6) If continuity is not present, repair or replace  wire 415A (para 2-40).  (7) Position wire 415A in fan terminal board.  (8) Tighten terminal 4 screw on fan terminal board.