TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  YES  NO  TEST OPTIONS  REASON FOR QUESTION  KNOWN INFO  4.  Fluorescent lights OK.  Circuit breaker CB8 OK.  Fan switch S35 OK.  Fan OK.  POSSIBLE PROBLEMS  Faulty wire 415.  Faulty wire 415A.  Faulty wire 1499H.  Faulty wire 3085X.  Faulty wire 3085F.  Faulty wire 3085Z.  Continuity Test or  STE/ICE-R #91  If continuity is not present,  wire 415 is faulty.  Is continuity present on  wire 415 from circuit  breaker CB8 to fan switch  S35 outlet box?  Repair or replace wire  415 (para 2-40).  YES  NO  TEST OPTIONS  REASON FOR QUESTION  KNOWN INFO  Continuity Test or  STE/ICE-R #91  5.  Fluorescent lights OK.  Circuit breaker CB8 OK.  Fan switch S35 OK.  Fan OK.  Wire 415 OK.  POSSIBLE PROBLEMS  Faulty wire 415A.  Faulty wire 1499H.  Faulty wire 3085X.  Faulty wire 3085F.  Faulty wire 3085Z.  If continuity is not present,  wire 415A is faulty.  Repair or replace wire  415A (para 2-40).  Is continuity present on  wire 415A from one end  to the other?  e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT)  2-1092 2-1092 2-1092 2-1092 2-1092