TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1091 2-1091 2-1091 2-1091 2-1091  CONTINUITY TEST  (1) Remove two screws and cover from outlet  box.  (2) Remove two screws and fan switch S35 from  outlet box.  (3) Position fan switch S35 to ON.  (4) Set multimeter to ohms.  (5) Connect positive (+) probe of multimeter to  lower terminal of fan switch S35.  (6) Connect negative (-) probe of multimeter to  upper terminal of fan switch S35 and note  reading on multimeter.  (7) If continuity is not present, replace fan switch  S35 (para 16-54).  RESISTANCE TEST  (1) Remove fan assembly (para 16-67).  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter to  fan connector terminal 4 screw.  (4) Connect negative (-) probe of multimeter to  fan connector terminal 2 screw and note  reading on multimeter.  (5) If 30-40 ohms resistance is not present,  replace fan (para 16-67).