TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  YES  NO  TEST OPTIONS  REASON FOR QUESTION  KNOWN INFO  2.  Continuity Test or  STE/ICE-R #91  Fluorescent lights OK.  Circuit breaker CB8 OK.  POSSIBLE PROBLEMS  Faulty fan switch S35.  Faulty fan.  Faulty wire 415.  Faulty wire 415A.  Faulty wire 1499H.  Faulty wire 3085X.  Faulty wire 3085F.  Faulty wire 3085Z.  Is continuity present  across fan switch S35?  If continuity is not present,  fan switch S35 is faulty.  Replace fan switch  S35 (para 16-54).  YES  NO  TEST OPTIONS  REASON FOR QUESTION  KNOWN INFO  3.  Fluorescent lights OK.  Circuit breaker CB8 OK.  Fan switch S35 OK.  POSSIBLE PROBLEMS  Faulty fan.  Faulty wire 415.  Faulty wire 415A.  Faulty wire 1499H.  Faulty wire 3085X.  Faulty wire 3085F.  Faulty wire 3085Z.  Is 30-40 ohms resistance  present from fan connector  terminal 2 to fan connector  terminal 4?  If resistance is too high or  too low, fan is faulty.  Replace fan (para 16-67).  Resistance Test or  STE/ICE-R #91  e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT)  2-1090 2-1090 2-1090 2-1090 2-1090