TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 36 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO 2. Continuity Test or STE/ICE-R #91 Fluorescent lights OK. Circuit breaker CB8 OK. POSSIBLE PROBLEMS Faulty fan switch S35. Faulty fan. Faulty wire 415. Faulty wire 415A. Faulty wire 1499H. Faulty wire 3085X. Faulty wire 3085F. Faulty wire 3085Z. Is continuity present across fan switch S35? If continuity is not present, fan switch S35 is faulty. Replace fan switch S35 (para 16-54). YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO 3. Fluorescent lights OK. Circuit breaker CB8 OK. Fan switch S35 OK. POSSIBLE PROBLEMS Faulty fan. Faulty wire 415. Faulty wire 415A. Faulty wire 1499H. Faulty wire 3085X. Faulty wire 3085F. Faulty wire 3085Z. Is 30-40 ohms resistance present from fan connector terminal 2 to fan connector terminal 4? If resistance is too high or too low, fan is faulty. Replace fan (para 16-67). Resistance Test or STE/ICE-R #91 e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) e99. M1079 FAN DOES NOT OPERATE (CONT) 2-1090 2-1090 2-1090 2-1090 2-1090