TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 321 of 1432

CONTINUITY TEST CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. TM 9-2320-365-20-2 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector J115 socket 6. (3) Connect negative (-) probe of multimeter to connector J119 socket r and note reading on multimeter. (4) Connect negative (-) probe of multimeter to all other sockets in connector J119 and note reading on multimeter. (5) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (6) If continuity is not present in step 3, or continuity is present in step 4 or step 5, replace WTEC II cab transmission harness (para 7-86). Change 1 2-1375