TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 303 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  wire 707A terminal lug on LIGHTS/BLACKOUT  OVERRIDE switch S33.  (3) Connect negative (-) probe of multimeter to  K36 relay base terminal 7 and note reading on  multimeter.  (4) If continuity is not present, repair or replace  wire 707A (para 2-40).  (5) If continuity is present, repair or replace wire  1511 (para 2-40).  (6) Position LIGHTS/BLACKOUT OVERRIDE switch  S33 to BLACKOUT (TM 9-2320-365-10).  (7) Close cover on relay box assembly.  (8) Tighten screw in cover.  2-1357/(2-1358 Blank) 2-1357/(2-1358 Blank) 2-1357/(2-1358 Blank) 2-1357/(2-1358 Blank) 2-1357/(2-1358 Blank)