TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1356 2-1356 2-1356 2-1356 2-1356 e120. M1079 FLUORESCENT LIGHTS DO NOT OPERATE IN BLACKOUT OVERRIDE MODE e120. M1079 FLUORESCENT LIGHTS DO NOT OPERATE IN BLACKOUT OVERRIDE MODE e120. M1079 FLUORESCENT LIGHTS DO NOT OPERATE IN BLACKOUT OVERRIDE MODE e120. M1079 FLUORESCENT LIGHTS DO NOT OPERATE IN BLACKOUT OVERRIDE MODE e120. M1079 FLUORESCENT LIGHTS DO NOT OPERATE IN BLACKOUT OVERRIDE MODE TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 YES NO 3. POSSIBLE PROBLEMS Fluorescent lights OK in BLACKOUT mode. LIGHTS/BLACKOUT OVERRIDE switch S33 OK. Wire 38 OK. If continuity is not present, wire 707A is faulty. If continuity is present, wire 1511 is faulty. Faulty wire 707A. Faulty wire 1511. Is continuity present on wire 707A from LIGHTS/ BLACKOUT OVERRIDE switch S33 to K36 relay base terminal 7? Repair or replace wire 707A (para 2-40). Repair or replace wire 1511 (para 2-40).