TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1353 2-1353 2-1353 2-1353 2-1353  CONTINUITY TEST  (1) Pull out circuit breaker CB10  (TM 9-2320-365-10).  (2) Loosen screw in cover.  (3) Open cover on relay box assembly.  (4) Set multimeter to ohms.  (5) Position LIGHTS/BLACKOUT OVERRIDE switch  S33 to BLACKOUT OVERRIDE  (TM 9-2320-365-10).  (6) Connect positive (+) probe of multimeter to wire  707A terminal lug on LIGHTS/BLACKOUT  OVERRIDE switch S33.  (7) Connect negative (-) probe of multimeter to wire  1511 terminal lug on LIGHTS/BLACKOUT  OVERRIDE switch S33 and note reading on  multimeter.  (8) If continuity is not present, replace LIGHTS/  BLACKOUT OVERRIDE switch S33 (para 16-56).