TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 297 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1351 2-1351 2-1351 2-1351 2-1351  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  110/208 vac IN connector pin C.  (3) Connect negative (-) probe of multimeter to  circuit breaker CB1 right input terminal and  note reading on multimeter.  (4) If continuity is not present, repair or replace  wire 502 (para 2-40).  (5) If continuity is present, troubleshoot 110 vac  power source.  (6) Position circuit breaker CB1 to OFF.  (7) Install cover on 110/208 VAC POWER  DISTRIBUTION PANEL with six screws.  (8) Install dust cover on 110/208 VAC power IN  connector.  (9) Position circuit breaker CB1 to ON.