TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1349 2-1349 2-1349 2-1349 2-1349 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to 110/208 vac ground. (3) Connect negative (-) probe of multimeter to terminal board TB3 wire 3085Y and note reading on multimeter. (4) If continuity is not present, repair or replace wire 3085Y (para 2-40). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to 110/208 vac IN connector pin A. (3) Connect negative (-) probe of multimeter to circuit breaker CB1 left input terminal and note reading on multimeter. (4) If continuity is not present, repair or replace wire 500 (para 2-40). CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to 110/208 vac IN connector pin B. (3) Connect negative (-) probe of multimeter to circuit breaker CB1 middle input terminal and note reading on multimeter. (4) If continuity is not present, repair or replace wire 501 (para 2-40).