TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1345 2-1345 2-1345 2-1345 2-1345 CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to 110/208 vac IN connector pin G1. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair or replace wire 3085N (para 2-40). CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to 110/208 vac IN connector pin G2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair or replace wire 3085P (para 2-40).