TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1341 2-1341 2-1341 2-1341 2-1341 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to right output terminal of circuit breaker CB1. (3) Connect negative (-) probe of multimeter to right input terminal of circuit breaker CB1 and note reading on multimeter. (4) If continuity is not present, replace circuit breaker CB1 (para 16-65). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to middle output terminal of circuit breaker CB1. (3) Connect negative (-) probe of multimeter to middle input terminal of circuit breaker CB1 and note reading on multimeter. (4) If continuity is not present, replace circuit breaker CB1 (para 16-65).