TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 286 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1340 2-1340 2-1340 2-1340 2-1340 e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT) e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT) e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT) e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT) e119. M1079 110 VAC POWER DOES NOT OPERATE (CONT) YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 12/24 vdc circuits OK. POSSIBLE PROBLEMS Faulty circuit breaker CB1. Faulty wire 1499N. Faulty wire 3085N. Faulty wire 3085P. Faulty wire 3085Q. Faulty wire 3085R. Faulty wire 3085Y. Faulty wire 500. Faulty wire 501. Faulty wire 502. If continuity is not present, circuit breaker CB1 is faulty. YES NO TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 12/24 vdc circuits OK. POSSIBLE PROBLEMS Faulty circuit breaker CB1. Faulty wire 1499N. Faulty wire 3085N. Faulty wire 3085P. Faulty wire 3085Q. Faulty wire 3085R. Faulty wire 3085Y. Faulty wire 500. Faulty wire 501. Faulty wire 502. If continuity is not present, circuit breaker CB1 is faulty. 2. 3. Is continuity present across circuit breaker CB1 middle terminal? Is continuity present across circuit breaker CB1 right terminal? Replace circuit breaker CB1 (para 16-65). Replace circuit breaker CB1 (para 16-65).