TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1322 2-1322 2-1322 2-1322 2-1322 KNOWN INFO YES NO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION 14. If continuity is not present, J237 negative binding post is faulty. If continuity is present, wire 3086 is faulty. Blackout lights OK. Emergency lights OK. Fuse OK. M1079 12/24 vdc power cable OK. Wire 1507 OK. Circuit breaker CB11 OK. Wire 49 OK. Positive binding post OK. Wire 3085L OK. Ground binding post OK. POSSIBLE PROBLEMS Faulty negative 24 vdc binding post. Faulty wire 3086. Is continuity present across J237 24 vdc negative (-) binding post? Replace negative binding post (para 16-52). Repair or replace wire 3086 (para 2-40). e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT)