TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 265 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1319 2-1319 2-1319 2-1319 2-1319 CONTINUITY TEST (1) Remove six screws and cover from 110/208 VAC POWER DISTRIBUTION PANEL. (2) Loosen screw in terminal board TB3. (3) Remove wire 3085L from terminal board TB3. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to J237 24 vdc ground (G) binding post. (6) Connect negative (-) probe of multimeter to terminal board TB3 wire 3085L and note reading on multimeter. (7) If continuity is not present, repair or replace wire 3085L (para 2-40). (8) Position wire 3085L in terminal board TB3. (9) Tighten screw in terminal board TB3. (10) Install cover on 110/208 VAC POWER DISTRIBUTION PANEL with six screws.