TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 264 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1318 2-1318 2-1318 2-1318 2-1318 KNOWN INFO YES NO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION 12. Is continuity present from J237 24 vdc ground (G) binding post to terminal board TB3 wire 3085L? If continuity is not present, wire 3085L is faulty. POSSIBLE PROBLEMS Faulty wire 3085L. Faulty negative 24 vdc binding post. Faulty wire 3086. Blackout lights OK. Emergency lights OK. Fuse OK. M1079 12/24 vdc power cable OK. Wire 1507 OK. Circuit breaker CB11 OK. Wire 49 OK. Positive binding post OK. Repair or replace wire 3085L (para 2-40). e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT)