TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 260 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1314 2-1314 2-1314 2-1314 2-1314  e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT)  KNOWN INFO  YES  NO  TEST OPTIONS  Continuity Test or  STE/ICE-R Test #91  REASON FOR QUESTION  10.  Is continuity present  from circuit breaker  CB11 wire 49 to J237  24 vdc positive (+)  binding post?  If continuity is not present,  wire 49 is faulty.  POSSIBLE PROBLEMS  Faulty wire 49.  Faulty positive 24 vdc  binding post.  Faulty wire 3085L.  Faulty negative 24 vdc  binding post.  Blackout lights OK.  Emergency lights OK.  Fuse OK.  M1079 12/24 vdc power  cable OK.  Wire 1507 OK.  Circuit breaker CB11 OK.  Repair or replace wire 49  (para 2-40).