TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 256 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1310 2-1310 2-1310 2-1310 2-1310 e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) KNOWN INFO YES NO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION If continuity is not present, wire 1507 is faulty. 8. Is continuity present from connector J173 pin G and H to circuit breaker CB11 wire 1507? POSSIBLE PROBLEMS Faulty wire 1507. Faulty circuit breaker CB11. Faulty wire 49. Faulty positive 24 vdc binding post. Faulty wire 3085L. Faulty negative 24 vdc binding post. Blackout lights OK. Emergency lights OK. Fuse OK. M1079 12/24 vdc power cable OK. Repair or replace wire 1507 (para 2-40).