TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1308 2-1308 2-1308 2-1308 2-1308 e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) KNOWN INFO YES NO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION Blackout lights OK. Emergency lights OK. Fuse OK. POSSIBLE PROBLEMS If continuity is not present, wire 1507 is faulty. 7. Faulty M1079 12/24 vdc power cable. Faulty circuit breaker CB11. Faulty wire 49. Faulty positive 24 vdc binding post. Faulty wire 3085L. Faulty negative 24 vdc binding post. Is continuity present from right end of fuse holder to connector P173 pin G and H? Repair wire 1507 (para 2-40) or replace M1079 12/24 vdc power cable (para 7-51).