TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 248 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1302 2-1302 2-1302 2-1302 2-1302 e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) KNOWN INFO YES NO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION Blackout lights OK. Emergency lights OK. J237 24 vdc binding post OK. Wire 49A OK. J236 24 vdc positive binding post OK. POSSIBLE PROBLEMS Faulty wire 3085AD. Faulty ground 24 vdc binding post. 4. Is continuity present from J237 ground (G) binding post to J236 ground (G) binding post? If continuity is not present, wire 3085AD is faulty. If continuity is present, J236 ground (G) binding post is faulty. Repair or replace wire 3085AD (para 2-40). Replace ground binding post (para 16-52).