TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 244 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1298 2-1298 2-1298 2-1298 2-1298 e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) e117. M1079 24 VDC BINDING POST(S) DOES NOT OPERATE (CONT) KNOWN INFO 2. Is continuity present from J237 positive (+) binding post to J236 positive (+) binding post? YES NO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION If continuity is not present, wire 49A is faulty. Blackout lights OK. Emergency lights OK. J237 24 vdc binding posts OK. POSSIBLE PROBLEMS Faulty wire 49A. Faulty positive 24 vdc binding post. Faulty wire 3085AD. Faulty ground 24 vdc binding post. Repair or replace wire 49A (para 2-40).