TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 240 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1294 2-1294 2-1294 2-1294 2-1294 e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R Test #91 10. YES NO Fan OK. Wire 400 OK. Wire 1499A OK. Wire 3085A OK. M1079 heater power cable OK. Wire 401 OK. Wire 1499R OK. Wire 3086C OK. M1079 heater thermostat cable OK. M1079 heater thermostat OK. POSSIBLE PROBLEMS Faulty M1079 heater control cable. Faulty M1079 heater. Troubleshoot M1079 heater (TM 5-4520-253-13). Is continuity present on M1079 heater control cable? Replace M1079 heater control cable (para 20-43). If continuity is not present, M1079 heater control cable is faulty. If continuity is present, M1079 heater is faulty.