TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1291 2-1291 2-1291 2-1291 2-1291 CONTINUITY TEST (1) Disconnect connector P245A from ROOM THERMO connector. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector P245A pin A. (4) Connect negative (-) probe of multimeter to connector J245 socket A and note reading on multimeter. (5) Connect positive (+) probe of multimeter to connector P245A pin B. (6) Connect negative (-) probe of multimeter to connector J245 socket B and note reading on multimeter. (7) Connect positive (+) probe of multimeter to connector P245A pin C. (8) Connect negative (-) probe of multimeter to connector J245 socket C and note reading on multimeter. (9) If continuity is not present in step 4, 6, or 8, replace M1079 heater thermostat cable (para 20-45). (10) Connect connector P245A to ROOM THERMO connector.