TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 236 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1290 2-1290 2-1290 2-1290 2-1290 e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R Test #91 8. YES NO Fan OK. Wire 400 OK. Wire 1499A OK. Wire 3085A OK. M1079 heater power cable OK. Wire 401 OK. Wire 1499R OK. Wire 3086C OK. POSSIBLE PROBLEMS Faulty M1079 heater thermostat cable. Fautly M1079 heater thermostat. Faulty M1079 heater control cable. Faulty M1079 heater. Is continuity present on M1079 heater thermostat cable? If continuity is not present, M1079 heater thermostat cable is faulty. Replace M1079 heater thermostat cable (para 20-45).