TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 230 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1284 2-1284 2-1284 2-1284 2-1284 e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R Test #91 5. YES NO Fan OK. Wire 400 OK. Wire 1499A OK. Wire 3085A OK. M1079 heater power cable OK. POSSIBLE PROBLEMS Faulty wire 401. Faulty wire 1499R. Faulty wire 3086C. Faulty M1079 heater thermostat cable. Faulty M1079 heater thermostat. Faulty M1079 heater control cable. Faulty M1079 heater. Is continuity present on wire 401 from THERMOSTAT connector P245 pin C to thermostat terminal 3? Repair or replace wire 401 (para 2-40). If continuity is not present, wire 401 is faulty.