TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1283 2-1283 2-1283 2-1283 2-1283 (1) Remove heater deflector/duct and hood (para 20-50). (2) Disconnect connector J244A from heater POWER RECEPTACLE connector. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector P244 pin A. (5) Connect negative (-) probe of multimeter to connector J244A socket A and note reading on multimeter. (6) Connect positive (+) probe of multimeter to connector P244 pin C. (7) Connect negative (-) probe of multimeter to connector J244A socket C and note reading on multimeter. (8) Connect positive (+) probe of multimeter to connector P244 pin D. (9) Connect negative (-) probe of multimeter to connector J244A socket D and note reading on multimeter. (10) If continuity is not present in step 5, 7, or 9, replace M1079 heater power cable (para 20-50). (11) Connect connector J244A to heater POWER RECEPTACLE connector. CONTINUITY TEST