TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1278 2-1278 2-1278 2-1278 2-1278 e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) e116. M1079 HEATER DOES NOT OPERATE (CONT) YES NO KNOWN INFO 2. REASON FOR QUESTION Continuity Test or STE/ICE-R Test #91 TEST OPTIONS Is continuity present on wire 1499A from terminal board TB4 to HEATER connector J244 socket C. Fan OK. Wire 400 OK. POSSIBLE PROBLEMS Repair or replace wire 1499A (para 2-40). If continuity is not present, wire 1499A is faulty. Faulty wire 1499A. Faulty wire 3085A. Faulty M1079 heater power cable. Faulty wire 401. Faulty wire 1499R. Faulty wire 3086C. Faulty M1079 heater thermostat cable. Faulty M1079 heater thermostat. Faulty M1079 heater control cable. Faulty M1079 heater.