TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1274 2-1274 2-1274 2-1274 2-1274 e115. M1079 AIR CONDITIONER DOES NOT OPERATE (CONT) e115. M1079 AIR CONDITIONER DOES NOT OPERATE (CONT) e115. M1079 AIR CONDITIONER DOES NOT OPERATE (CONT) e115. M1079 AIR CONDITIONER DOES NOT OPERATE (CONT) e115. M1079 AIR CONDITIONER DOES NOT OPERATE (CONT) TEST OPTIONS REASON FOR QUESTION KNOWN INFO Continuity Test or STE/ICE-R #91 6. Fluorescent lights OK. 110 vac outlets OK. Circuit breaker CB2 OK. Wire 1500 OK. Wire 1501 OK. Wire 1502 OK. Wire 1499M OK. POSSIBLE PROBLEMS YES NO Troubleshoot air conditioner (TM 5-4120-384-14). Replace M1079 A/C power cable (para 20-82). If continuity is not present, M1079 A/C power cable is faulty. Is continuity present on M1079 A/C power cable? Faulty M1079 A/C power cable. Faulty air conditioner.