TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 219 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1273 2-1273 2-1273 2-1273 2-1273  CONTINUITY TEST  (1) Loosen screw in terminal board TB4.  (2) Remove wire 1499M from terminal board TB4.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter to  wire 1499M.  (5) Connect negative (-) probe of multimeter to air  conditioner connector J242 socket D and note  reading on multimeter.  (6) If continuity is not present, repair or replace  wire 1499M (para 2-40).  (7) Install wire 1499M on terminal board TB4.  (8) Tighten screw in terminal board TB4.  (9) Install cover on 110/208 VAC POWER  DISTRIBUTION PANEL with six screws.