TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1264 2-1264 2-1264 2-1264 2-1264 1. START YES NO KNOWN INFO TEST OPTIONS INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). AC power disconnected (TM 9-2320-365-10). Personnel Required (2) Continuity Test or STE/ICE-R #91 REASON FOR QUESTION e115. M1079 AIR CONDITIONER DOES NOT OPERATE Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P TM 5-4120-384-14 Fluorescent lights OK. 110 vac outlets OK. POSSIBLE PROBLEMS Is continuity present across circuit breaker CB2? If continuity is not present, circuit breaker CB2 is faulty. Replace circuit breaker CB2 (para 16-64). Faulty circuit breaker CB2. Faulty wire 1500. Faulty wire 1501. Faulty wire 1505. Faulty wire 1499. Faulty M1079 A/C power cable. Faulty air conditioner.