TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 205 of 1432
TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2  2-1259 2-1259 2-1259 2-1259 2-1259  CONTINUITY TEST  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  one end of external negative field telephone  binding post.  (3) Connect negative (-) probe of multimeter to  other end of external negative field telephone  binding post and note reading on multimeter.  (4) If continuity is not present, replace external  negative field telephone binding post  (para 16-51).  NOTE  (5) Install cover on 110/208 vac power entry panel  with 16 washers, lockwashers, and screws.  NOTE  (6) Install cover on 110/208 vac power entry panel  with 28 washers, lockwashers, and screws.  Perform step (5) on van bodies  serial number 191 and higher.  Perform step (6) on van body  serial numbers 001 through  190.