TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1257 2-1257 2-1257 2-1257 2-1257 CONTINUITY TEST NOTE (1) Remove 28 screws, lockwashers, washers, and cover from 110/208 vac power entry panel. Discard lockwashers. NOTE (2) Remove 16 screws, lockwashers, washers, and cover from 110/208 vac power entry panel. Discard lockwashers. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to one end of external positive field telephone binding post. (5) Connect negative (-) probe of multimeter to other end of external positive field telephone binding post and note reading on multimeter. (6) If continuity is not present, replace external positive field telephone binding post (para 16-51). Perform step (1) on van body serial numbers 001 through 190. Perform step (2) on van bodies serial number 191 and higher.