TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 186 of 1432
TM 9-2320-365-20-2  2-1240 Change 1  e113. M1079 EMERGENCY LIGHT(S) DOES NOT ILLUMINATE (CONT)  6.  KNOWN INFO TEST OPTIONS  Continuity Test or  STE/ICE-R Test #91  REASON FOR QUESTION  POSSIBLE PROBLEMS  Blackout lights OK.  All emergency lights do  not operate.  Wire 1505A OK.  Faulty relay K41.  Faulty wire 38A.  Faulty relay K36.  Is continuity present from  K41 relay base terminal 8  to terminal 2?  If continuity is not present,  relay K41 is faulty.  NO  Replace relay K41  (para 16-62).  YES