Change 1 2-1233 TM 9-2320-365-20-2 CONTINUITY TEST (1) Remove four screws and lens from base. (2) Remove gasket from base. (3) Remove lamp from base. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to center contact of lamp. (6) Connect negative (-) probe of multimeter to lamp base and note reading on multimeter. (7) If continuity is not present, replace lamp (16-58). (8) Install lamp in base. DS78 J163,P163 DS79 DS96 J165, P165 J166, P166 J167, P167 DS97 Location Number Connector RH Side LH Side Front Rear Table 2-15. M1079 Emergency Light Locations and Connector Numbers NOTE All emergency light lamps are tested the same way. Refer to Table 2-15. M1079 Emergency Light Locations and Connector Numbers for details. Emergency light DS78 shown.