TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 177 of 1432
Change 1 2-1231 TM 9-2320-365-20-2 (1) Disconnect AC power (TM 9-2320-365-10). (2) Push in circuit breaker CB11 (TM 9-2320-365-10). (3) Push in circuit breaker CB10 (TM 9-2320-365-10). (4) Position INTERIOR LIGHTS switch S32 to ON (TM 9-2320-365-10). (5) Position LIGHTS/BLACKOUT OVERRIDE switch S33 to BLACKOUT OVERRIDE (TM 9-2320-365-10). (6) Check to see if any emergency light illuminates. (7) If all emergency lights do not illuminate, go to step 5 of this fault. (8) Position LIGHTS/BLACKOUT OVERRIDE switch S33 to BLACKOUT (TM 9-2320-365-10). (9) Position INTERIOR LIGHTS switch S32 to OFF (TM 9-2320-365-10). (10) Pull out circuit breaker CB10 (TM 9-2320-365-10). (11) Pull out circuit breaker CB11 (TM 9-2320-365-10).