TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download

Page 171 of 1432

TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 TM 9-2320-365-20-2 2-1225 2-1225 2-1225 2-1225 2-1225 CONTINUITY TEST NOTE (1) Remove four screws and lens from base. (2) Remove gasket from base. (3) Remove lamp from base. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to center contact of lamp base. (6) Connect negative (-) probe of multimeter to lamp base and note reading on multimeter. (7) If continuity is not present, replace lamp (para 16-58). (8) Install lamp in base. (9) Install gasket on base. (10) Install lens on base with four screws. LOCATION NUMBER CONNECTORS RH side LH side DS75 DS76 J162, P162 J164, P164 Both blackout light lamps are tested the same way. Refer to Table 2-14. M1079 Blackout Light Locations and Connector Numbers for details. Blackout light DS75 shown. Table 2-14. M1079 Blackout Light Locations and Connector Numbers