NO TM 9-2320-365-20-2 2-1220 Change 1 e111. M1079 110 VAC OUTLET J230 DOES NOT OPERATE (CONT) 7. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION Replace relay K35 (para 16-62). 110 VAC outlets J231, J232, J233, and J234 OK. 110 VAC outlet J235 does not operate. Circuit breaker CB9 OK. Wire 701C OK. Faulty wire 702C. Faulty relay K35. If continuity is not present, wire 702C is faulty. If continuity is present, relay K35 is faulty. Is continuity present on wire 702C from K35 relay base terminal 6 to 110 VAC receptacle J230 supply pole? Repair or replace wire 702C (para 2-40). YES