TM 9-2320-365-20-2 2-1218 Change 1 e111. M1079 110 VAC OUTLET J230 DOES NOT OPERATE (CONT) 6. KNOWN INFO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION POSSIBLE PROBLEMS 110 VAC outlets J231, J232, J233, and J234 OK. 110 VAC outlet J235 does not operate. Circuit breaker CB9 OK. Faulty wire 701C. Faulty wire 702C. Faulty relay K35. Is continuity present on wire 701C from circuit breaker CB9 to K35 relay base terminal 9? If continuity is not present, wire 701C is faulty. NO Repair or replace wire 701C (para 2-40). YES