TM-9-2320-365-20-2 LMTV Unit Maintenance Manual M1078 Series - Volume 2 Download
Page 160 of 1432
TM 9-2320-365-20-2 2-1214 Change 1 e111. M1079 110 VAC OUTLET J230 DOES NOT OPERATE (CONT) 4. KNOWN INFO TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION Repair or replace wire 3085AC (para 2-40). Repair or replace wire 3085J (para 2-40). YES NO 110 VAC outlets J231, J232, J233, and J234 OK. 110 VAC outlet J235 OK. Circuit breaker CB9 OK. Wire 701C OK. Wire 702C OK. Relay K35 OK. 110 VAC receptacle J230 OK. Wire 1499D OK. POSSIBLE PROBLEMS Faulty wire 3085J. Faulty wire 3085AC. Is continuity present on wire 3085J from 110 VAC receptacle J230 to terminal board TB3? If continuity is not present, wire 3085J is faulty. If continuity is present, wire 3085AC is faulty.